Marke | DADISICK |
Modell | EZ-SCREEN LS-S-Serie | SLLCE40-1680-S/SLLCR40-1680-S/SLLCP40-1680, SLLE40-1190-S/SLLR40-1190-S/SLLP40-1190, SLLE40-1400-S/SLLR40-1400-S/SLLP40-1400, SLLCE40-1540-S/SLLCR40-1540-S/SLLCP40-1540, SLLCE40-1190-S/SLLCR40-1190-S/SLLCP40-1190, SLLE40-1050-S/SLLR40-1050-S/SLLP40-1050, SLLCE40-1260-S/SLLCR40-1260-S/SLLCP40-1260, SLLCE40-1820-S/SLLCR40-1820-S/SLLCP40-1820, SLLCE40-1750-S/SLLCR40-1750-S/SLLCP40-1750, SLLE40-1470-S/SLLR40-1470-S/SLLP40-1470, SLLE40-1820-S/SLLR40-1820-S/SLLP40-1820, SLLCE40-1050-S/SLLCR40-1050-S/SLLCP40-1050, SLLE40-1750-S/SLLR40-1750-S/SLLP40-1750, SLLCE40-1400-S/SLLCR40-1400-S/SLLCP40-1400, SLLCE40-1610-S/SLLCR40-1610-S/SLLCP40-1610, SLLCE40-1120-S/SLLCR40-1120-S/SLLCP40-1120, SLLE40-1330-S/SLLR40-1330-S/SLLP40-1330, SLLCE40-1330-S/SLLCR40-1330-S/SLLCP40-1330, SLLCE40-1470-S/SLLCR40-1470-S/SLLCP40-1470, SLLE40-1120-S/SLLR40-1120-S/SLLP40-1120, SLLE40-1260-S/SLLR40-1260-S/SLLP40-1260, SLLE40-1610-S/SLLR40-1610-S/SLLP40-1610, SLLE40-1540-S/SLLR40-1540-S/SLLP40-1540, SLLCE40-1120-S/SLLCR40-1120-S/SLLCP40-1120, SLLCE40-1750-S/SLLCR40-1750-S/SLLCP40-1750, SLLE40-1680-S/SLLR40-1680-S/SLLP40-1680 |
Serie: | LS-S-Serie |
Auflösung: | 40 mm |
Reichweite: | 0,1-12 m |
Schutzfeldhöhe: | 1050-1820 mm |
2 Sicherheitsausgänge (OSSD): | 2 PNP |
Ansprechzeit: | 11,2 bis 15,9 ms |
Verbindungstyp: | M12 |
Sicherheitsstufe: | UL, CE, PLe4 |
Aktualisierungszeit | 2025/4/3 |
Marke | Aus dem Netzwerk | DADISICK | |||
Modelle | Emitter | Empfänger | Paar | ||
SLLE40-1050-S | SLLR40-1050-S | SLLP40-1050 | |||
SLLCE40-1050-S | SLLCR40-1050-S | SLLCP40-1050 | |||
SLLCE40-1120-S | SLLCR40-1120-S | SLLCP40-1120 | |||
SLLE40-1120-S | SLLR40-1120-S | SLLP40-1120 | |||
SLLCE40-1120-S | SLLCR40-1120-S | SLLCP40-1120 | |||
SLLE40-1190-S | SLLR40-1190-S | SLLP40-1190 | |||
SLLCE40-1190-S | SLLCR40-1190-S | SLLCP40-1190 | |||
SLLCE40-1260-S | SLLCR40-1260-S | SLLCP40-1260 | |||
SLLE40-1260-S | SLLR40-1260-S | SLLP40-1260 | |||
SLLE40-1330-S | SLLR40-1330-S | SLLP40-1330 | |||
SLLCE40-1330-S | SLLCR40-1330-S | SLLCP40-1330 | |||
SLLE40-1400-S | SLLR40-1400-S | SLLP40-1400 | |||
SLLCE40-1400-S | SLLCR40-1400-S | SLLCP40-1400 | |||
SLLE40-1470-S | SLLR40-1470-S | SLLP40-1470 | |||
SLLCE40-1470-S | SLLCR40-1470-S | SLLCP40-1470 | |||
SLLCE40-1540-S | SLLCR40-1540-S | SLLCP40-1540 | |||
SLLE40-1540-S | SLLR40-1540-S | SLLP40-1540 | |||
SLLCE40-1610-S | SLLCR40-1610-S | SLLCP40-1610 | |||
SLLE40-1610-S | SLLR40-1610-S | SLLP40-1610 | |||
SLLCE40-1680-S | SLLCR40-1680-S | SLLCP40-1680 | |||
SLLE40-1680-S | SLLR40-1680-S | SLLP40-1680 | |||
SLLCE40-1750-S | SLLCR40-1750-S | SLLCP40-1750 | |||
SLLE40-1750-S | SLLR40-1750-S | SLLP40-1750 | |||
SLLCE40-1750-S | SLLCR40-1750-S | SLLCP40-1750 | |||
SLLCE40-1820-S | SLLCR40-1820-S | SLLCP40-1820 | |||
SLLE40-1820-S | SLLR40-1820-S | SLLP40-1820 | |||
Strahlabstand | 40 mm | 20 mm | |||
Geschützte Höhe | 1050 mm/1120 mm/1190 mm/1260 mm/1330 mm/1400 mm/1470 mm/1540 mm/1610 mm/1680 mm/1750 mm/1820 mm | 1080 mm/1160 mm/1240 mm/1320 mm/1400 mm/1480 mm/1560 mm/1640 mm/1720 mm/1800 mm | |||
Reichweite | 0,1-12 m | 0,3-15 m | |||
Ansprechzeit | 11,2 bis 15,9 ms | ≤15ms | |||
Ausgabemethode | 2 PNP | 2 PNP | |||
Zuverlässigkeit und Langlebigkeit | IP65/IP67 | IP65 | |||
Konnektor | M12 | M12 | |||
Gehäusequerschnitt | 36 x 45 mm | 28 x 30 mm | |||
Sicherheitszertifikat | UL, CE, PLe4 | TÜV, UL, CE, RoHS, GB | |||
Wir sind in der Lage, die spezifischen Anschlusskonfigurationen jeder Marke mit hoher Genauigkeit zu reproduzieren. |